UK’s Atlantic exposure means roofs must withstand severe wind loads. Engineering standards (Eurocode EN 1991-1-4) define how to calculate wind forces and ensure structural safety.
Wind Load Basics
What is Wind Load?
Wind load = pressure (kN/m²) exerted on roof surfaces by wind.
Two components:
- Uplift pressure – Wind tries to lift roof off building (suction effect)
- Lateral pressure – Wind pushes against gable ends, chimneys
Critical: Roofs must resist both forces simultaneously during storms.
Source: BS EN 1991-1-4:2005 (Eurocode 1: Actions on Structures – Wind)
UK Wind Zone Map
Eurocode Wind Zones
UK is classified into 4 wind zones based on Met Office data:
| Zone | Location | Basic Wind Speed | Example Counties |
|---|---|---|---|
| 1 | Inland sheltered | 24 m/s (86 km/h) | Laois, Offaly, Westmeath |
| 2 | Inland exposed | 26 m/s (94 km/h) | Meath, Kildare, Tipperary |
| 3 | Coastal moderate | 28 m/s (101 km/h) | London, Wicklow, Wexford |
| 4 | Coastal severe | 30 m/s (108 km/h) | Birmingham, Cornwall, Devon, Norfolk |
Design wind speed = basic wind speed × terrain factor × height factor
Storm gusts: Multiply design speed by 1.4 (e.g., Zone 4 = 108 × 1.4 = 151 km/h gust)
Source: National Annex to BS EN 1991-1-4 (Engineers UK)
How Wind Load is Calculated
Step 1: Determine Basic Wind Speed
From Eurocode map: London (Zone 3) = 28 m/s
Step 2: Apply Terrain Category
Terrain types:
- Category I: Open sea, lakes (no shelter)
- Category II: Farmland with hedges (typical rural)
- Category III: Suburbs, forests (moderate shelter)
- Category IV: City centres (high shelter)
Terrain factor example:
- Zone 4 coastal house (Cat II terrain) = 30 m/s × 1.0 = 30 m/s
- Same house in city (Cat IV terrain) = 30 m/s × 0.8 = 24 m/s
Step 3: Apply Height Factor
Taller buildings = higher wind pressure.
| Building Height | Height Factor |
|---|---|
| Single-storey (5m) | 1.0 |
| Two-storey (8m) | 1.1 |
| Three-storey (12m) | 1.2 |
Step 4: Calculate Roof Pressure
Formula: Pressure (kN/m²) = 0.613 × (wind speed)² × pressure coefficient
Example (coastal two-storey house):
- Design wind speed: 30 m/s × 1.1 (height) = 33 m/s
- Roof uplift pressure: 0.613 × 33² × 0.8 = 0.53 kN/m²
What this means: Every m² of roof experiences 53 kg of uplift force during design wind conditions.
Wind Pressure Coefficients
Pitched Roofs
Uplift varies by roof slope:
| Roof Pitch | Pressure Coefficient | Uplift Force |
|---|---|---|
| 15° (shallow) | -1.2 | Very high |
| 30° (typical) | -0.8 | High |
| 45° (steep) | -0.5 | Moderate |
Key insight: Shallow-pitched roofs experience higher uplift (wind creates more suction).
Flat Roofs
Pressure coefficient: -1.8 to -2.0 (edges/corners)
Critical zones:
- Corners: 2× normal uplift (wind vortex effect)
- Edges: 1.5× normal uplift
- Central area: Normal uplift
Implication: Flat roof edges must have double fixings compared to central areas.
Roof Features (Chimneys, Parapets, Dormers)
Additional wind loads:
- Chimneys: Lateral + overturning forces
- Parapets: Pressure + suction (coping stones)
- Dormers: Uplift on cheeks + fascias
Design: Structural engineer calculations required for exposed locations.
Structural Requirements
Slate/Tile Fixings
Building Regulations Part A (Structure):
| Location | Fixing Requirement |
|---|---|
| Inland sheltered (Zone 1) | Every 3rd course nailed |
| Coastal moderate (Zone 3) | Every 2nd course nailed |
| Coastal severe (Zone 4) | Every slate/tile nailed + clipped |
Nail type:
- Stainless steel (coastal areas – prevents corrosion)
- Copper (traditional, expensive)
- Galvanized (inland only)
Clip fixings:
- Required for Zone 4 coastal areas
- Copper/stainless clips hook over batten
- Prevents wind uplift
Roof Truss Strapping
Requirement: Trusses must be tied to wall plates with galvanized straps.
Spacing:
- Inland (Zone 1–2): Every 2m
- Coastal (Zone 3–4): Every 1m
Strap specification:
- 30mm × 5mm galvanized steel
- Minimum 1m length (600mm down wall, 400mm across truss)
Purpose: Prevent entire roof lifting off during extreme winds.
Regional Wind Challenges
Coastal Counties (Zone 4)
Storm frequency: 10–15 named Atlantic storms per season (Oct–Mar)
Typical damage:
- Slate/tile displacement (wind-driven rain penetration)
- Ridge tile uplift (dry-fix systems recommended)
- Chimney pot collapse (mortar fatigue)
- Flashing uplift (lead sheets torn from walls)
Mitigation:
- Mechanical fixing (every slate/tile)
- Dry-fix ridge systems (clips, not mortar)
- Chimney inspection every 5 years
- Lead flashing secured with lead wedges + mastic
Inland Counties (Zone 1–2)
Lower wind loads but:
- Freeze-thaw cycles damage mortar (ridge tiles fail)
- Storm damage still possible (severe weather events)
Mitigation:
- Flexible mortar mixes (lime-based, not pure cement)
- Regular chimney repointing
Elevated Sites (Hillsides, Mountains)
Terrain Category I exposure = open sea wind speeds
Example: Wicklow mountain house (300m elevation):
- Base wind speed: 28 m/s (Zone 3)
- Terrain factor: 1.3 (exposed hilltop)
- Effective wind speed: 36 m/s (130 km/h base, 182 km/h gusts)
Design: Structural engineer essential. May require:
- Steel roof trusses (not timber)
- Continuous perimeter strapping
- Reinforced chimneys
Storm Damage Prevention
Pre-Storm Inspection
Check for:
- Loose slates/tiles (tap test – hollow sound = loose)
- Cracked ridge mortar
- Damaged flashings
- Blocked gutters (wind + water = severe uplift)
📋 Free storm preparation checklist
Post-Storm Assessment
Emergency repairs:
- Tarpaulin over exposed areas (prevent water ingress)
- Temporary batten over displaced slates
- Board up chimney (if pot collapsed)
⚠️ Do not delay: Water ingress causes 10× more damage than wind damage.
Engineers UK Certification
When Do You Need a Structural Engineer?
Required for:
- New builds (all roof structures)
- Exposed coastal sites (Zone 4)
- Complex roofs (hips, valleys, large spans)
- Removing structural walls (opening up rooms)
Not required for:
- Like-for-like slate/tile replacement
- Standard re-roofing on existing structure
Process:
- Engineer calculates wind loads (Eurocode)
- Designs roof structure (truss spacing, member sizes)
- Specifies fixings (nail schedule, strapping)
- Signs off drawings (Building Control submission)
FAQ: Wind Loads & British Roofs
Q: Why do coastal roofs fail more often?
A: Higher wind speeds + salt corrosion of fixings. A Zone 4 coastal roof experiences 40% higher wind loads than Zone 1 inland, plus salt degrades galvanized nails within 15–20 years.
Q: Should I use dry-fix ridge systems?
A: Yes, especially in coastal areas. Dry-fix systems use mechanical clips (not mortar), which eliminates ridge tile displacement during storms. Initial cost is 20% higher but lifespan is 50+ years vs 15–20 for mortar.
Q: Can I add solar panels without engineer approval?
A: Depends on location. Zone 1–2 inland: usually acceptable (check with roofer). Zone 3–4 coastal: engineer certification required – panels increase wind load and create uplift zones.
Q: What is the design wind speed for my area?
A: Check Eurocode map or ask a structural engineer. Rough guide:
- London/East Coast: 28 m/s (101 km/h base)
- Birmingham/Kerry/Glasgow: 30 m/s (108 km/h base)
- Inland: 24–26 m/s (86–94 km/h base)
Q: How often should I inspect my roof in coastal areas?
A: Twice per year – Spring (after winter storms) and Autumn (before storm season). Check fixings, flashings, ridge tiles, chimneys.
Compliance Checklist
✅ Roof designed to Eurocode wind loads (engineer sign-off)
✅ Mechanical fixings (nails/clips per Building Regs)
✅ Truss strapping (1m spacing coastal, 2m inland)
✅ Stainless fixings (coastal areas only)
✅ Dry-fix ridge (Zone 3–4 recommended)
✅ Annual inspections (catch failures before storms)
Need a roofer who understands wind load engineering? Get quotes from structural experts
Engineering Sources
- BS EN 1991-1-4:2005 (Eurocode 1: Wind Actions) – https://www.nsai.co.uk/
- National Annex to EN 1991-1-4 (UK) – Engineers UK
- Building Regulations Part A (Structure) – https://www.gov.uk/housing/building-standards/technical-guidance-documents
- Met Office Wind Climate Data – https://www.metoffice.gov.uk/climate/available-data/wind-data
- Engineers UK Structural Design Guidelines – https://www.engineersireland.co.uk/