UK’s Building Regulations Part L (Conservation of Fuel & Energy) sets minimum insulation standards for roofs. The 2025 requirements are among the strictest in Europe.
Part L 2025: Roof Insulation U-Value Requirements
U-Value Definition
U-value = rate of heat transfer through a building element (W/m²K)
Lower U-value = better insulation = less heat loss
Current Standards (2025)
| Building Type | Roof Element | Maximum U-Value | Minimum Insulation Depth |
|---|---|---|---|
| New Dwellings | Pitched roof (attic) | 0.16 W/m²K | 300mm mineral wool |
| New Dwellings | Flat roof | 0.16 W/m²K | 150mm PIR insulation |
| New Dwellings | Rafter insulation | 0.16 W/m²K | 200mm PIR + 50mm internal |
| Extensions | All roof types | 0.16 W/m²K | Same as new builds |
| Renovations (>25%) | All roof types | 0.16 W/m²K | Upgrade required |
| Existing (voluntary) | Attic | 0.16 W/m²K | Energy Saving Trust grant standard |
Source: gov.uk Technical Guidance Document Part L 2025
Historical Comparison
| Era | Standard | Typical Depth | U-Value |
|---|---|---|---|
| Pre-1970s | None | 0mm | 2.3 W/m²K |
| 1980s | 50mm | 50mm mineral wool | 0.6 W/m²K |
| 2000s | 100mm | 100mm mineral wool | 0.35 W/m²K |
| 2011 | 200mm | 200mm mineral wool | 0.20 W/m²K |
| 2019 | 250mm | 250mm mineral wool | 0.18 W/m²K |
| 2025 | 300mm | 300mm mineral wool | 0.16 W/m²K |
Trend: Standards tightening 30% every 10 years.
How to Achieve 0.16 W/m²K
Method 1: Attic/Loft Insulation (Pitched Roof)
Installation layers:
- Between joists: 100mm mineral wool (first layer)
- Cross-layer: 200mm mineral wool (perpendicular to joists)
- Air gap: 50mm above insulation (ventilation)
Total depth: 300mm
Materials:
- Mineral wool (Rockwool/Knauf): £8–£12/m², R-value 0.037 W/mK
- Glass wool (Isover): £6–£10/m², R-value 0.035 W/mK
- PIR boards (rigid): £25–£35/m², R-value 0.022 W/mK (thinner option)
U-value calculation:
- 300mm mineral wool: R-value = 0.3m ÷ 0.037 = 8.1 m²K/W
- U-value = 1 ÷ (8.1 + 0.17*) = 0.13 W/m²K ✅ (exceeds 0.16 requirement)
*0.17 = surface resistance + air gap + deck
Method 2: Flat Roof Insulation
Warm deck system (most common):
- Structural deck (concrete/timber)
- Vapor control layer
- 150mm PIR insulation boards (Kingspan/Xtratherm)
- Waterproof membrane (EPDM/GRP)
U-value calculation:
- 150mm PIR: R-value = 0.15m ÷ 0.022 = 6.8 m²K/W
- U-value = 1 ÷ (6.8 + 0.14*) = 0.14 W/m²K ✅
*0.14 = surface resistance + deck
Alternative (cold deck):
- Insulation below deck (between joists)
- Requires 50mm ventilation gap above insulation
- More complex, rarely used for new builds
Method 3: Rafter Insulation (Room-in-Roof)
Challenge: Limited space between rafters (typically 100–150mm).
Hybrid solution:
- Between rafters: 100mm PIR boards
- Below rafters: 50mm PIR + 12.5mm plasterboard
- Breathable membrane: Above rafters (vapor escape)
U-value calculation:
- 150mm total PIR: R-value = 6.8 m²K/W
- U-value = 1 ÷ (6.8 + 0.14) = 0.14 W/m²K ✅
Alternative (external insulation):
- Add 50mm PIR above rafters (sarking board)
- Reduces ceiling height internally
Insulation Material Comparison
| Material | R-Value (W/mK) | Depth for 0.16 U-Value | Cost (£/m²) | Lifespan | Eco Rating |
|---|---|---|---|---|---|
| PIR Boards | 0.022 | 140mm | £30 | 50 yrs | Moderate |
| Mineral Wool | 0.037 | 300mm | £10 | 50 yrs | Good |
| Glass Wool | 0.035 | 280mm | £8 | 50 yrs | Good |
| Wood Fiber | 0.040 | 350mm | £40 | 50 yrs | Excellent |
| Sheep’s Wool | 0.038 | 320mm | £50 | 50 yrs | Excellent |
| EPS (Polystyrene) | 0.034 | 270mm | £12 | 50 yrs | Poor (fire risk) |
Best value: Mineral wool (affordable, non-combustible)
Best performance: PIR boards (thinnest for same R-value)
Most sustainable: Wood fiber (carbon-negative, 100% recyclable)
Compliance & Certification
When Part L Applies
Mandatory compliance:
✅ New builds – All dwellings (sign-off required)
✅ Extensions >40m² – Building Control inspects
✅ Major renovations – >25% of building envelope
✅ Change of use – E.g., barn conversion to dwelling
Not required:
❌ Like-for-like re-roofing – Replacing slates/tiles without structural change
❌ Repairs – Fixing leaks, repointing ridges
❌ Minor extensions – <40m² conservatories (subject to planning)
Inspection & Certification
Step 1: Design (Architect/Engineer)
- U-value calculations submitted with planning application
- Building Control reviews compliance
Step 2: Installation (Contractor)
- Approved insulation materials (CE marking)
- Correct depth/layers (inspector may measure)
Step 3: Sign-Off (Completion)
- Certificate of Compliance issued by builder
- Building Control spot-checks (10–20% of projects)
Step 4: EPC Assessment (New Builds Only)
- Energy Saving Trust assessor measures insulation depth
- EPC certificate issued (A1–G rating)
Common Non-Compliance Issues
1. Insufficient Depth (Most Common)
Problem: Contractor installs 200mm instead of 300mm
Consequence:
- U-value = 0.20 W/m²K (fails 0.16 standard)
- EPC rating drops 1 grade (A3 → B1)
- Building Control rejects sign-off
Fix: Add 100mm cross-layer (£500–£1,000)
2. Compressed Insulation
Problem: Storage items in attic compress insulation
Consequence:
- 300mm compressed to 150mm = 50% R-value loss
- U-value rises to 0.30 W/m²K
Fix: Remove items, add attic floor boards over raised joists
3. Gaps at Eaves/Soffits
Problem: Insulation doesn’t extend to eaves (thermal bridging)
Consequence:
- Cold spots → condensation → mold
- Heat loss at perimeter
Fix: Fill gaps with expanding foam + mineral wool
4. Missing Vapor Control Layer (Flat Roofs)
Problem: No vapor barrier below insulation
Consequence:
- Moisture condenses inside insulation → reduced R-value
- Structural timber rot
Fix: Retrofit vapor control layer (requires roof stripping)
Energy Saving Trust Grant Requirements (Voluntary Upgrades)
Attic Insulation Grant (£1,600)
Eligibility:
- Home built before 2011
- Current insulation <200mm
- EPC cert required (pre- and post-work)
Standard:
- Upgrade to 300mm (0.16 W/m²K)
- Use Energy Saving Trust-approved materials
- Registered contractor only
Payback: 3–5 years (energy savings)
Rafter Insulation Grant (£3,200)
Eligibility:
- Home built before 2011
- Room-in-roof/converted attic
- EPC cert required
Standard:
- Achieve 0.16 W/m²K (hybrid system)
- Breathable membrane required
- Fire-rated materials
Payback: 5–8 years
Deep Retrofit Grant (£25,000)
Eligibility:
- Improve home by 2+ EPC grades (e.g., D2 → B2)
- Roof insulation + walls + windows + heating
Roof component:
- Must achieve 0.16 W/m²K minimum
- Can include green roof, solar PV
Payback: 10–15 years (combined measures)
Energy Saving Trust grant application guide
FAQ: Part L Roof Insulation
Q: Do I need 300mm if re-roofing my home?
A: Not legally (if built pre-2011), but recommended. Energy Saving Trust grants cover £1,600 of cost, payback is 3–5 years. EPC rating improves (helps resale).
Q: Can I use 150mm PIR instead of 300mm mineral wool?
A: Yes – PIR has better R-value per mm. 150mm PIR ≈ 300mm mineral wool. More expensive (£30/m² vs £10/m²) but saves attic headroom.
Q: What if my rafters are only 100mm deep?
A: Use hybrid system: 100mm PIR between rafters + 50mm below rafters + external sarking board. Achieves 0.16 U-value.
Q: Does Part L apply to listed buildings?
A: Protected structures exempt (conservation overrides energy efficiency). Planning office decides on case-by-case basis.
Q: How do I prove compliance for Building Control?
A: Keep:
- Material delivery receipts (CE marking)
- U-value calculation (architect/engineer)
- Installation photos (depth measurement)
- EPC certificate (new builds)
Energy Savings: Insulation Impact
Heating Cost Reduction
Scenario: 3-bed semi-detached, 100m² roof, gas heating
| Insulation Level | U-Value | Annual Heat Loss | Heating Cost/Year | EPC Rating |
|---|---|---|---|---|
| None (1960s) | 2.3 W/m²K | 5,800 kWh | £750 | E2 |
| 100mm (2000s) | 0.35 W/m²K | 900 kWh | £120 | C3 |
| 300mm (2025) | 0.16 W/m²K | 410 kWh | £55 | A3 |
Savings (None → 300mm): £695/year
Payback (£1,500 cost - £1,600 grant): Immediate (net profit)
Carbon Reduction
300mm insulation upgrade:
- Heating reduction: 5,400 kWh/year
- Carbon savings: 1.0 tonnes CO₂/year (gas heating)
- Lifetime savings (50 years): 50 tonnes CO₂
Equivalent to: Planting 1,250 trees
Conclusion: Meeting 2025 Standards
For new builds/extensions:
- 300mm attic insulation (mineral wool)
- 150mm flat roof insulation (PIR)
- 200mm rafter insulation (hybrid PIR system)
For existing homes (voluntary):
- Energy Saving Trust grant: £1,600–£3,200
- Payback: 3–5 years
- EPC improvement: 2–3 grades
For homeowners:
- Hire Energy Saving Trust-registered contractors
- Request U-value calculations
- Keep compliance records
Need a Part L-compliant roofing contractor? Get quotes from certified professionals
Official Sources
- gov.uk Technical Guidance Document Part L – https://www.gov.uk/housing/building-standards/technical-guidance-documents
- Energy Saving Trust Better Energy Homes Standards – https://www.energysavingtrust.org.uk/home-energy/home-energy-grants/
- Building Control Act 2007 – https://www.legislation.gov.uk/eli/2007/act/21/enacted/en/html
- BS EN ISO 6946:2017 (U-Value Calculation) – https://www.nsai.co.uk/